ADAM™ rWBC2

Residual Leukocyte Counter

ADAM™ rWBC2 automatically counts the number of residual white blood cells (rWBC) in leukoreduced blood products for transfusion.

KEY FEATURES & BENEFITS
- 45 seconds for counting residual leukocyte
- Easy to use
- Accurate and reliable result (R2 correlation value is more than 0.99 against lab results)

New standard of residual leukocyte counting 
 



ADAM rWBC2 ensures the number of residual leukocyte meets the standards used to minimize complications associated with the transfusions performed in hospitals.








ADVANTAGE #1

45 seconds for counting residual leukocyte



All procedures are automated once the sample loaded slide is inserted into the device.
It takes only 45 seconds to count the residual leukocytes.
In combination with a disposable microfluidic slide, the operation of ADAM™ rWBC2 is extremely simple and cost-effective.
Warm-up time and messy cleaning is no longer necessary.

 

 


ADVANTAGE #2

New technology behind the Accuracy of ADAM rWBC2

ADAM rWBC2 is a precise, automated optical system capable of fluorescent image analysis. ADAM rWBC2 use propidium iodide (PI) staining.
The ADAM rWBC2 automatically focuses on the slide and the stained cells are taken by the movement of the automatic X-Y stage.
The ADAM™ rWBC2 analyzes and reports a result in using integral image analysis software.

By averaging results, ADAM™ rWBC2 produces accurate counting results in the analysis of low concentration of leukoreduced blood products.
Automated cell counting eliminates user bias or subjective interpretation
that can be found when counting residual leukocytes using other methods.

  








ADVANATAGE #3

Substantially equivalent to flow cytometry

Refer to the comparison of residual blood cell enumeration methods between flow cytometry (Leucocount)
and ADAM™
-rWBC series in using different amounts of white blood cells aliquots.
This comparison was performed using both RBC and platelet samples.









  • Product name / Cat. No.

    ADAM-rWBC2 / ADAM-rWBC2

  • Voltage

    DC 12V

  • Detection method

    4W Green LED

  • Weight

    7.0 kg

  • Size (LxWxH)

    277 X 276 X 270 mm

  • Data export

    PC connection

  • Analysis time

    45 sec/test

  • BLOOD PRODUCT / ADAM™ rWBC2

    ADAM-rWBC2 does not get turned on. 

    Please disconnect then reconnect the adaptor and check if LED is lit on the power button. Wait until the LED is turned off and then press the button for three seconds.
  • BLOOD PRODUCT / ADAM™ rWBC2

    There are error messages. 

    Remove the power cord from the outlet and wait for 2 ~ 3 seconds. Then, plug the power cord into the socket and turn on ADAM-rWBC2.